CORVUS SYSTEMS, INC.

TRANSPORTER MODEL 8010-10440

NIC Type

OmniNet (proprietary)

Network Transfer Rate

Unidentified

Data Bus

8-bit ISA

Topology

Linear Bus

Wire Type

Shielded/Unshielded twisted pair

Boot ROM

Available

CONNECTIONS

Function

Label

Unshielded or shielded twisted pair via 1/8" plug

CN1

USER CONFIGURABLE SETTINGS

Setting

Label

Position

»

Factory configured - do not alter

E2

Pins 1 & 2 closed

NODE ADDRESS

Setting

U14/1

U14/2

U14/3

U14/4

U14/5

U14/6

0

On

On

On

On

On

On

1

Off

On

On

On

On

On

2

On

Off

On

On

On

On

3

Off

Off

On

On

On

On

4

On

On

Off

On

On

On

59

Off

Off

On

Off

Off

Off

60

On

On

Off

Off

Off

Off

61

Off

On

Off

Off

Off

Off

62

On

Off

Off

Off

Off

Off

63

Off

Off

Off

Off

Off

Off

Note: A total of 64 node address settings are available. The switches are a binary representation of the decimal node addresses. U14/6 is the Most Significant Bit and switch U14/1 is the Least Significant Bit. The switches have the following decimal values: U14/6=32, U14/5=16, U14/4=8, U14/3=4, U14/2=2, U14/1=1. Turn off the switches and add the values of the switches that are off to obtain the correct node ID. (Off=1, On=0)

BIAS SELECTION

Setting

U14/7

U14/8

Normal

Off

Off

Biased

On

On

Note:Only one machine per network should be set to biased.

BASE I/O ADDRESS

Setting

E1/A

E1/B

E1/C

E1/D

 

240h

Closed

Open

Open

Open

»

248h

Open

Closed

Open

Open

 

250h

Open

Open

Closed

Open

 

258h

Open

Open

Open

Closed

Note:E1 is a set of solder contacts. To change the address, you must cut the trace on E1/C andhard-wire a jumper with a soldering gun.