COMPU-SHACK PRODUCTION, GMBH

CS-ETHERNET BUSMASTER-KARTE

NIC Type:

Ethernet

Transfer Rate:

10Mbps

Data Bus:

16-bit ISA

Topology:

Linear Bus

Wiring Type

AUI transceiver via DB-15 port

RG58A/U 50ohm coaxial

Boot ROM

Available

DMA SELECT - J2 & J3

Channel

Jumper A

Jumper B

Jumper C

Jumper D

Jumper E

Jumper F

Jumper G

»

DMA5

Open

Open

Closed

Open

Open

Open

Open

 

DMA0

Open

Open

Open

Open

Open

Open

Closed

 

DMA1

Open

Open

Open

Open

Open

Closed

Open

 

DMA2

Open

Open

Open

Open

Closed

Open

Open

 

DMA3

Open

Open

Open

Closed

Open

Open

Open

 

DMA6

Open

Closed

Open

Open

Open

Open

Open

 

DMA7

Closed

Open

Open

Open

Open

Open

Open

Note:The corresponding jumpers on both J2 and J3 are closed when designated. J2 is for DRQ and J3 is for DACK.

WIRING TYPE SELECT - J5

Setting

Jumper A

jumper B

Jumper C

Jumper D

Jumper E

Jumper F

BNC

1 & 2 closed

1 & 2 closed

1 & 2 closed

1 & 2 closed

1 & 2 closed

1 & 2 closed

AUI

2 & 3 closed

2 & 3 closed

2 & 3 closed

2 & 3 closed

2 & 3 closed

2 & 3 closed

BNC TYPE

Setting

J6/jumper A

J6/jumper B

»

RG58A/U 50ohm coaxial

Pins 2 & 3 closed

Pins 2 &3 closed

 

RG62A/U 93ohm coaxial

Pins 1 & 2 closed

Pins 1 & 2 closed

INTERRUPT SELECT - J8

IRQ

A

B

C

D

E

F

G

H

I

»

IRQ3

Open

Open

Open

Open

Open

Open

Open

Open

Closed

 

IRQ4

Open

Open

Open

Open

Open

Open

Open

Closed

Open

 

IRQ5

Open

Open

Open

Open

Open

Open

Closed

Open

Open

 

IRQ7

Open

Open

Open

Open

Open

Closed

Open

Open

Open

 

IRQ9

Open

Open

Open

Open

Closed

Open

Open

Open

Open

 

IRQ10

Open

Open

Open

Closed

Open

Open

Open

Open

Open

 

IRQ11

Open

Open

Closed

Open

Open

Open

Open

Open

Open

 

IRQ12

Open

Closed

Open

Open

Open

Open

Open

Open

Open

 

IRQ15

Closed

Open

Open

Open

Open

Open

Open

Open

Open

I/O ADDRESS

Address

SW1/1

SW1/2

SW1/3

SW1/4

SW1/5

»

300h

Off

On

On

On

On

 

200h

On

On

On

On

On

 

210h

On

On

On

On

Off

 

220h

On

On

On

Off

On

 

230h

On

On

On

Off

Off

 

240h

On

On

Off

On

On

 

250h

On

On

Off

On

Off

 

260h

On

On

Off

Off

On

 

270h

On

On

Off

Off

Off

 

280h

On

Off

On

On

On

 

290h

On

Off

On

On

Off

 

2A0h

On

Off

On

Off

On

 

2B0h

On

Off

On

Off

Off

 

2C0h

On

Off

Off

On

On

 

2D0h

On

Off

Off

On

Off

 

2E0h

On

Off

Off

Off

On

 

2F0h

On

Off

Off

Off

Off

 

310h

Off

On

On

On

Off

 

320h

Off

On

On

Off

On

 

330h

Off

On

On

Off

Off

 

340h

Off

On

Off

On

On

 

350h

Off

On

Off

On

Off

 

360h

Off

On

Off

Off

On

I/O ADDRESS

Address

SW1/1

SW1/2

SW1/3

SW1/4

SW1/5

370h

Off

On

Off

Off

Off

380h

Off

Off

On

On

On

390h

Off

Off

On

On

Off

3A0h

Off

Off

On

Off

On

3B0h

Off

Off

On

Off

Off

3C0h

Off

Off

Off

On

On

3D0h

Off

Off

Off

On

Off

3E0h

Off

Off

Off

Off

On

3F0h

Off

Off

Off

Off

Off

FACTORY CONFIGURED SETTINGS

Switch

Setting

SW1/6

N/A

SW1/7

N/A

SW1/8

N/A